Products
HDMI and VGA and DVI to LVDS Industrial LCD Controller Board
  • HDMI and VGA and DVI to LVDS Industrial LCD Controller BoardHDMI and VGA and DVI to LVDS Industrial LCD Controller Board
  • HDMI and VGA and DVI to LVDS Industrial LCD Controller BoardHDMI and VGA and DVI to LVDS Industrial LCD Controller Board

HDMI and VGA and DVI to LVDS Industrial LCD Controller Board

SKY-TDM HDMI and VGA and DVI to LVDS Industrial LCD Controller Board is a cost-optimized display controller for standard industrial applications requiring HDMI, VGA, or DVI input to LVDS panel output. Unlike multi-interface boards with DP/Type-C/eDP support, this solution focuses on the three most common video interfaces found in legacy and current industrial PCs.Designed for equipment manufacturers who need reliable LVDS panel driving without paying for unused features, this board delivers stable image quality, flexible timing configuration, and OEM/ODM customization for panel matching and firmware tuning.

Many industrial display projects require converting standard PC video outputs---HDMI, VGA, or DVI---to LVDS signals that drive industrial TFT LCD panels. While multi-interface boards support DP, Type-C, and eDP, most factory equipment (PLCs, industrial PCs, and legacy controllers) still uses HDMI, VGA, or DVI as primary outputs.

SKY-TDM HDMI and VGA and DVI to LVDS Industrial LCD Controller Board addresses this specific need. It accepts the three most common video sources found on industrial computers and drives LVDS panels without requiring DP-to-HDMI adapters or Type-C conversion cables---saving cost and reducing potential failure points in the signal chain.

We have supplied this board to equipment manufacturers for HMI panel upgrades, CNC machine display replacements, and medical cart display integration where standard video outputs need to connect to LVDS industrial panels. For customers already using HDMI, VGA, or DVI sources and LVDS panels, this board provides a straightforward solution without paying for unused DP, Type-C, or eDP features.


Key Features

1. Three Standard Inputs for Industrial PCs

- HDMI supports modern industrial PCs and embedded systems

- VGA connects to legacy controllers and older hardware

- DVI provides digital signal path for industrial workstations

- No DP or Type-C support means lower cost for standard applications

2. LVDS Panel Driving Optimized

- Supports single/dual-channel LVDS outputs up to 1920×1080 @ 60Hz

- Compatible with 6-bit, 8-bit, and 10-bit LVDS panels

- Panel voltage selectable (3.3V/5V/12V) for various LCD models

- Adjustable timing parameters for panel-specific requirements

3. Industrial-Grade Signal Integrity

- Low EMI design reduces interference with nearby equipment

- Wide DC input (8-25V) for 12V or 24V industrial power systems

- Integrated backlight driver with PWM brightness control

- Stable image output under factory power fluctuations

4. Simplified Integration for OEMs

- Standard JST 2x15 LVDS output connector matches common panel cables

- Compact PCB size fits most industrial display enclosures

- Single-board solution eliminates external converter boxes

- Long-term lifecycle supply for multi-year equipment production


Interfaces and Dimensions

HDMI and VGA and DVI to LVDS Industrial LCD Controller Board interfaces and dimensions


JST 2x15 Pin LVDS Output Interface

Pin Signal Pin Signal
1 VCC(3.3/5/12V) 2 VCC(3.3/5/12V)
3 VCC(3.3/5/12V) 4 NC
5 GND 6 GND
7 TXO0- 8 TXO0+
9 TXO1- 10 TXO1+
11 TXO2- 12 TXO2+
13 GND 14 GND
15 TXOCLK- 16 TXOCLK+
17 TXO3- 18 TXO3+
19 TXE0- 20 TXE0+
21 TXE1- 22 TXE1+
23 TXE2- 24 TXE2+
25 GND 26 GND
27 TXECLK- 28 TXECLK+
29 TXE3- 30 TXE3+


6-Pin 2.0mm Backlight Interface

Pin Signal
1 GND
2 GND
3 PWM
4 ON/OFF
5 12V
6 12V


Typical Applications

Our HDMI and VGA and DVI to LVDS Industrial LCD Controller Board are primarily designed for industrial applications, offering exceptional stability. They are widely used across various industries, including industrial automation HMI panels, CNC machine operator terminals, medical diagnostic and patient monitoring equipment, industrial panel PCs and embedded controllers, open-frame touch monitors, self-service kiosks and interactive terminals, retail POS systems, on-board transportation displays, and smart factory production equipment.


When to Choose This Board vs. Multi-Interface Board

Which Controller Board Fits Your Project?

SKY-TDM offers two industrial LCD controller boards. Here is how to choose:

Choose This Board (HDMI/VGA/DVI to LVDS) if:

- Your video sources are HDMI, VGA, or DVI only (no DP/Type-C required)

- Your LCD panel uses LVDS interface (no eDP panels)

- You need a cost-optimized solution for standard industrial applications

- You want to avoid paying for DP Alt Mode, Type-C, or eDP features

- You are upgrading existing equipment that already has HDMI/VGA/DVI outputs

Choose the Multi-Interface Board (HDMI/DP/VGA/Type-C to LVDS/eDP) if:

- Your system includes DisplayPort or USB Type-C video sources

- You need eDP panel support

- You are developing a new platform with multiple video input requirements

- Your application requires 4K resolution support

- You need maximum interface flexibility for future-proofing

For most industrial automation, medical, and kiosk applications with standard PC outputs and LVDS panels, this board provides the optimal balance of functionality and cost.


Why Choose SKY-TDM

Industrial-Grade Reliability

Built with premium electronic components to ensure stable, long-duration operation in harsh industrial environments.

One-Stop Display Ecosystem

We provide LCD panels, touch screens, controller boards, optical bonding, and custom display cables, enabling single-source procurement for your entire display assembly.

Comprehensive OEM & ODM Customization

Our team fully supports your customization needs. We can tailor the product's physical appearance, interfaces, signal cables, and power input/output according to your specific requirements.

Long-Term Stable Supply

Strict Bill of Materials (BOM) management prevents sudden component obsolescence, which is crucial for industrial devices requiring multi-year production support.

Dedicated Engineering Support

Our team will follow up with you from the prototype validation phase through to mass production, continuously tracking testing issues and providing technical solutions.


Quality Assurance

All of our HDMI and VGA and DVI to LVDS Industrial LCD Controller Board undergo standardized inspection processes and a comprehensive suite of rigorous testing procedures. We perform 100% full functional verification, signal integrity and output stability testing, continuous burn-in testing (available upon request), power supply stability cycling tests, and complete interface communication verification. These steps ensure the usability and integrity of every product before shipment. Our strict quality screening minimizes the risk of field failures for industrial equipment OEMs in end-user applications.


FAQ

Q1: What is the main difference between this board and SKY-TDM's multi-interface board?

A: This board focuses on HDMI, VGA, and DVI inputs with LVDS output---the three most common interfaces found on industrial PCs and legacy controllers. It offers a cost-optimized solution for standard applications where DP, Type-C, and eDP are not required.

Q2: Can this board support resolutions higher than 1920×1080?

A: This board is optimized for industrial LVDS panels up to 1920×1080 @ 60Hz. For 4K or higher resolution applications with eDP panels, we recommend our multi-interface board which supports eDP outputs.

Q3: Can I use this board with both 12V and 24V power supplies?

A: Yes. The board supports a wide DC input range of 8V to 25V, making it compatible with both 12V and 24V industrial power systems commonly found in factory automation and medical equipment.

Q4: How do I know if my LCD panel is compatible?

A: Please provide your LCD panel model number. Our engineering team will verify LVDS pin mapping, panel voltage, timing parameters, and resolution compatibility. We can also provide matching LVDS cables.

Q5: Is this board compatible with resistive and capacitive touch screens?

A: Yes. We support touch interface integration for both PCAP and resistive touch screens via USB, I²C, or UART. The board can be paired with your touch controller as part of a complete display solution.

Q6: What is the typical lifecycle for HDMI and VGA and DVI to LVDS Industrial LCD Controller Board?

A: This board is designed with long-term component sourcing for industrial equipment that requires 8-15 years of production support. We maintain strict BOM control to prevent sudden component obsolescence.

Q7: Do you provide panel-matching firmware?

A: Yes. We customize firmware for your specific LCD panel timing, resolution, and operating parameters. This ensures plug-and-play integration with your display panel.


Contact Us

Are you sourcing dependable industrial LCD controller boards for your embedded display project?

Whether you require standard HDMI/VGA/DVI to LVDS driver boards or fully customized display assemblies, SKY-TDM's engineering team supports your project from initial concept through mass manufacturing.

Please provide the following details within your enquiry:

• Exact LCD panel model number

• Display size and native resolution

• Required video input interfaces

• Operating voltage specifications

• Touchscreen type (if applicable)

• Target application and operating environment

• Estimated annual order quantity

• Detailed customization requirements

Our engineers will evaluate your specifications, deliver matched hardware recommendations, technical drawings and competitive quotations within 24 hours.

Factory Address: No. 39, Tangkeng 2nd Road, Tangkeng Community, Biling Sub-district, Pingshan District, Shenzhen

Year Established: 2009

Factory Scale: Area of 3,000+ square meters / 50+ employees

Key Certifications: ISO9001, ISO13485, IATF16949

WhatsApp: +86 150 0209 4095


Hot Tags: HDMI and VGA and DVI to LVDS Industrial LCD Controller Board
Send Inquiry
Contact Info
  • Address

    No. 39, Tangkeng 2nd Road, Tangkeng Community, Biling Sub-district, Pingshan District, Shenzhen City, Guangdong Province, China

Fill in the inquiry form to get competitive quotations for Touch Panel, Open‑Frame Touchscreen Monitor, LCD Display and LCD Driver Board. Please specify size, quantity and custom demands, our sales team will respond promptly.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy